UAB Coagulation Service

 

   

 

 

Home
Anouncements
Contact Us
Clinical Conditions
Guidelines
Links
Test Menu
Test Order Form
UAB Pathology Dept

 


 

 

 

 

 

 

 

 

 

 

 

 
 

UAB Coagulation Service Individual Assay List

     

Euglobulin Clot Lysis Time

Primary Name Euglobulin Clot Lysis Time
Synonym Euglobulin Lysis
Synonym --
Contraction ECLT
Contraction --
Contraction --
UAB Procedure Number 2500420
CPT Code 85360
Specimen

Collect one (1) blue-stopper tube (3.2% sodium citrate), filled to specified volume. Do not underfill or overfill.

Specimen Management Centrifuge blue-stopper tube within 1 hour of collection, separate plasma and test or quick-freeze at -70°C.
Specimen Accepted Daily including weekends
Times Available 0730-1600; deliver to lab by 0900 for same-day results
Test Performed Monday-Friday
Available Stat? Pathologist's approval required.
Description The ECLT is a clot-based test of the fibrinolytic system. A result less than 2 hours indicates an increase in fibrinolysis that could correlate with bleeding. Prolonged results indicate inadequate fibrinolysis.
Reference Interval 2-6 hours
Critical Value --
Therapeutic Range --
Follow-up Test Plasminogen activity, plasminogen activator inhibitor 1, tissue plasminogen activator
Associated With Venous thrombosis
Associated With Bleeding disorders

 

 

 

 
Home | UAB Home | Pathology Home | Contact Us |